The company mainly produces HXGN series high voltage ring network cabinet, KYN28 series middle mounted cabinet, YB series prefabricated substation, GGD, GCK, GCL, MNS, GCS, BFC series low voltage cabinet, XM, XL series distribution box power cabinet, various frequency conversion cabinets, control cabinets, XQJ series bridge, bus duct and other power distribution products.
(1) Purpose
JP series multi-functional low-voltage integrated distribution box is widely used in substations, factories, industrial and mining enterprises, large power plants, petroleum and chemical enterprises, large steel plants, high-rise building power centers, and 10/0.4KV outdoor substation low-voltage side of urban and rural power grids; It has the functions of power distribution, power metering, data acquisition, voltage monitoring, over-current protection, low-voltage lightning protection, power failure protection and reactive compensation; It is also applicable to the corresponding on-site power distribution control, and can also be used as a supporting auxiliary device for other power distribution equipment. The product complies with GB7251.12-2013 Low voltage Switchgear and Control Equipment in Sets - Part 2: Power Switchgear and Control Equipment in Sets and GB/T 15576-2008 Low voltage Complete Reactive Power Compensator.
⑵ Product characteristics
1) Automatic dynamic target value setting can prolong the service life of compensation capacitor and switching device, thus improving the service life of the whole equipment;
2) Remote automatic judgment and alarm for capacitor and switching device fault or damage;
3) It has overvoltage, overload, undervoltage, undercurrent, short circuit and other protection functions;
4) When the capacitor is switched on or off, the data transmission of cell carrier integrated reading will not be affected;
5) Three phase imbalance automatic fine adjustment, zero crossing switching, no inrush current.
(3) Technical conditions
Rated voltage: AC380V
Rated frequency: 50HZ
Compensation capacity: configured according to the actual capacity of the actual substation transformer
Main wiring: Δ/ Y wiring
Altitude: below 2000m;
Ambient temperature: - 20 ℃~ 65 ℃;
Relative humidity: 5~95%, the relative humidity can reach 100% in a short time at 25 ℃;
Installation inclination: ≤ 5%
Maximum daily temperature difference: ≤ 15K
The surrounding air is free from obvious dust, smoke, corrosive or combustible gas, water vapor or salt pollution